CryptoPlus ProID
3B
7E
94
00
00
80
25
A0
00
00
00
28
56
80
10
21
00
??
??
mask: FFFFFDFFFFFFFFFFFFFFFFFFFFFFFFFF800000
4
Total reports
100%
Success rate
2012
First report
2015-09-23
Last report
ATR Analysis
ISO 7816-3 · local
Full analysis on smartcard-atr.apdu.fr ↗
Convention
direct
Protocol
T=0
Baud rate (TA1)
Fi=512, Di=8, fmax=5MHz, 64.00 cycles/ETU
Guard time (TC1)
0 etu
Historical bytes
8025A0000000285680102100????
COMPACT-TLV (category 0x80)
| # | Byte | Name | Description |
|---|---|---|---|
| 0 | 3B | TS | Direct convention (TS = 3B) |
| 1 | 7E | T0 | Format byte: 14 historical bytes, Y1=0b0111 (TA1=present, TB1=present, TC1=present, TD1=absent) |
| 2 | 94 | TA1 | TA1: Fi=512, Di=8 → 64 cycles/ETU at 5MHz |
| 3 | 00 | TB1 | TB1: deprecated Vpp programming voltage parameter |
| 4 | 00 | TC1 | TC1: extra guard time = 0 etu |
| 5 | 80 | T1 | Historical byte 1 |
| 6 | 25 | T2 | Historical byte 2 |
| 7 | A0 | T3 | Historical byte 3 |
| 8 | 00 | T4 | Historical byte 4 |
| 9 | 00 | T5 | Historical byte 5 |
| 10 | 00 | T6 | Historical byte 6 |
| 11 | 28 | T7 | Historical byte 7 |
| 12 | 56 | T8 | Historical byte 8 |
| 13 | 80 | T9 | Historical byte 9 |
| 14 | 10 | T10 | Historical byte 10 |
| 15 | 21 | T11 | Historical byte 11 |
| 16 | 00 | T12 | Historical byte 12 |
| 17 | ?? | T13 | Historical byte 13 masked |
| 18 | ?? | T14 | Historical byte 14 masked |